Prepared by: Assistant Lecturer Lina Hussein Ali
Rapporteur, Department of Civil Engineering, College of Engineering, Al-Mustaqbal University
Abstract: In-situ soil exploration is the first step in any construction project, because the cost of an error in estimating ground conditions usually exceeds the cost of the exploration itself many times over. This article reviews the main field tests: the Standard Penetration Test (SPT), the Cone Penetration Test (CPT/CPTu), the field vane test, the plate load test, and tests within boreholes. It then explains how their results are interpreted and corrected, and the limits of relying on them. It concludes that the best exploration program is one that combines more than one test and pairs field results with laboratory tests and engineering judgment.
Keywords: in-situ exploration, standard penetration test, cone penetration test, vane test, interpretation of results.
1. Introduction
Soil properties vary from one site to another, and even within the same site, and they are affected by geological history and the groundwater level. Laboratory samples alone are not enough to describe soil behavior, because extracting and preparing a sample may alter its original structure. For this reason, boreholes and samples are supplemented by tests carried out at the site itself, which provide continuous information with depth and reduce reliance on disturbed samples. The exploration program is determined by the type of structure, its loads, and the design stage. It begins with a desk study and site reconnaissance, then a preliminary investigation to determine the general stratigraphic sequence, then a detailed investigation with samples and suitable field tests, and it ends with comparison against laboratory results and the preparation of the report.
2. The Main Field Tests
The Standard Penetration Test is one of the most widely used tests. It is performed during drilling by dropping a standard hammer on a split-barrel sampler and recording the number of blows needed to drive it a specified distance (the N value). This value is then used to estimate properties such as strength and compressibility. Its procedures are defined in the standard ASTM D1586 [1]. The fundamental problem is that the N value is affected by equipment and procedures. Skempton showed that the energy delivered to the split-barrel sampler, and therefore the blow count, can differ even with good site control. He recommended an internationally standard value of 60% of the free-fall energy, so the corrected value is called N₆₀, and the value normalized at an effective stress of 100 kPa is called (N₁)₆₀ [2]. To correct for the effect of effective overburden stress, factors such as those of Liao and Whitman are used [3]. For this reason, SPT results from different sites or different organizations must not be compared before these corrections are applied.
In the cone penetration test, a cone-tipped probe is pushed into the soil at a constant rate of about 2 cm/s [4]. It measures the tip resistance and the friction on the sleeve, and in its CPTu form it also measures pore water pressure. The cone resistance is corrected by the relation qt = qc + u₂(1 − a), where u₂ is the pore pressure behind the cone and a is the area ratio [5]. The test has the advantage of giving a continuous profile with depth, but it has limits noted in its reference guide: the high cost of equipment, the need for skilled operators, the absence of a soil sample, and difficulty of penetration in gravel layers and cemented layers [5]. For this reason, it is recommended to perform several cone soundings first to determine the stratigraphic profile, and then to take selective samples from the critical layers that the test has revealed [5].
The field vane test is used to measure the undrained shear strength in soft to medium clay. A vane with four blades is pushed into the soil and rotated to measure the torque required to shear it, and the strength is then measured again after the soil is remolded in order to estimate its sensitivity. Its results may overestimate the strength in some types of clay, so reduction factors determined according to the soil properties are applied to them. The plate load test measures the bearing capacity and the amount of settlement under a given load. It is one of the tests closest to the actual behavior of a foundation, but its depth of influence is limited by the size of the plate, so it does not reflect layers deeper than that. To these tests are added tests within the borehole, such as the pressuremeter and the flat dilatometer, which give elastic moduli and lateral stress, and the dynamic cone penetration test, which provides a simple alternative for shallow sites [6].
3. Interpretation of Results
Field tests do not measure soil properties directly. They measure the soil's response to a penetration or shearing process, and the readings are then converted into properties through empirical or theoretical relations. An example is estimating the undrained shear strength from cone resistance using the relation Su = (qt − σv)/Nk, where σv is the overburden stress and Nk is an empirical factor that varies with soil type. Because these correlations were derived from specific soils, it is advisable to calibrate them locally with laboratory results before generalizing them.
The CPT makes it possible to classify soil behavior using a chart that relates normalized tip resistance to normalized friction ratio [4]. This is a classification of soil behavior, not of its grain-size texture. In his update of the system, Robertson noted that most cone-based classification systems use textural descriptions such as sand and clay, which causes confusion [7]. Therefore, the classification obtained from the field test may differ from the laboratory classification of the same sample, and this is not necessarily a contradiction.
The sources of uncertainty in this field are numerous. Differences in equipment and procedures affect the SPT [2]. Effective stress and stress history affect the readings. The tests may miss thin lenses of clay or sand because the layers are not homogeneous. And what is measured at a single point may be generalized to the whole area of the site. The soil report should therefore document the equipment, its efficiency, and the corrections applied, and it should state the limits of each test explicitly.
4. Recommendations
It is recommended to set up an exploration program that combines more than one test instead of relying on a single test, and to document the hammer efficiency and the SPT procedures and apply the corrections before interpretation. It is also recommended to use the CPT to determine the stratigraphic sequence and then select the sampling locations accordingly, to calibrate empirical correlations with local laboratory results whenever possible, and to state the limits of the tests and the sources of uncertainty in the soil report.
5. Conclusion
No single field test suits all conditions. The SPT provides a sample and a widely used measurement, the CPT provides a continuous picture of the stratigraphic profile, the vane test is specific to soft clay, and the plate load test comes close to the actual behavior of a foundation. The value of the results increases when they are corrected, calibrated, and compared with laboratory data, and when the engineer understands their limits. The quality of exploration is measured not by the number of tests, but by how well they suit the problem of the site and by the quality of their interpretation.
References
ASTM International. Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils (ASTM D1586).
Skempton, A. W. (1986). Standard penetration test procedures and the effects in sands of overburden pressure, relative density, particle size, ageing and overconsolidation. Géotechnique, 36(3), 425–447. https://doi.org/10.1680/geot.1986.36.3.425
Liao, S. S. C., & Whitman, R. V. (1986). Overburden correction factors for SPT in sand. Journal of Geotechnical Engineering, ASCE, 112(3), 373–377.
Robertson, P. K. (2009). Interpretation of cone penetration tests — a unified approach. Canadian Geotechnical Journal, 46(11), 1337–1355. https://doi.org/10.1139/T09-065
Robertson, P. K., & Cabal, K. L. (2009). Guide to Cone Penetration Testing for Geotechnical Engineering (3rd ed.). Gregg Drilling & Testing, Inc.
Lutenegger, A. J. (2021). In Situ Testing Methods in Geotechnical Engineering. CRC Press.
Robertson, P. K. (2016). Cone penetration test (CPT)-based soil behaviour type (SBT) classification system — an update. Canadian Geotechnical Journal, 53(12), 1910–1927.